亚洲精品无码久久久久久久宅男,四虎最新地址无码,91精品人妻一区二区,成人做爰黄A片免费看直播室

<label id="h3ra4"></label>
<span id="h3ra4"></span><span id="h3ra4"></span>

        1. <label id="h3ra4"><meter id="h3ra4"></meter></label>
          歡迎訪問詠繹電子科技(蘇州)有限公司網(wǎng)站,我們竭誠為您提供合格產(chǎn)品和專業(yè)的服務!服務熱線:0512-68051240
          產(chǎn)品分類·product

          我們相信合格的產(chǎn)品是信譽的保證!

          相關(guān)文章·articles

          致力于成為合格的解決方案供應商!

          產(chǎn)品中心/ products

          您的位置:首頁  -  產(chǎn)品中心  -    -    -  FLUKE PM3380B示波器

          FLUKE PM3380B示波器

          0

          • 產(chǎn)品型號:
          • 廠商性質(zhì):代理商
          • 更新時間:2025-02-22
          • 訪  問  量:1008
          立即咨詢

          聯(lián)系電話:0512-68051240

          產(chǎn)品詳情

           
           The Fluke PM 3380B ...94B series are the world's first AutoRanging Digital Storage Oscilloscopes with a complete Analog Oscilloscope built in.

          Fluke CombiScopes® are a powerful combination of a genuine analog oscilloscope and a powerful digital oscilloscope in one instrument. Designed to fit any budget, there are 5 models in the CombiScope B series: three 2 channel models with bandwidths of 60, 100 or 200 MHz and two 4 channel models with 100 or 200 MHz bandwidth.

          Fluke CombiScopes offer the best of both worlds:

          PM3380BAnalog Mode Specifications
          Vertical Deflection (PM 3380B/90B) Input Channels: 2 Channels + Ext Trig View 
          Frequency Response:  100 MHz 
          Deflection Coefficient: Ch1 & Ch2 (all models): 2 mV/div . 5 V/div in a 1-2-5 sequence or 2 mV/div to 12.5 V/div calibrated continuously variable 
          Rise Time (Calculated):  1.75 ns
          Error Limit: 1.3% (Measured over center 6 divisions) 
          Input Impedance: (all models, all channels) 1 MΩ Â±1% // 25 pf ±2 pf 
          Max. Rated input voltage: In 1 MΩ position: 150 Vrms CAT II
          In 50Ω position: 5 Vrms; 50V ac peak ( max of 50 mJ during any 100 ms interval. 
           
          Vertical Deflection (PM 3384B/94B) Input Channels: 4 Channels
          Frequency Response: 200 MHz 
          Deflection Coefficient: Ch1 & Ch2 (all models): 2 mV/div . 5 V/div in a 1-2-5 sequence or 2 mV/div to 12.5 V/div calibrated continuously variable 
          Ch3 & Ch4 (PM 3384B/94B): 2 mV/div . 5 V/div in a 1-2-5 sequence or 2 mV/div to 12.5 V/div calibrated continuously variable 
          Rise Time (Calculated): 1.75 ns 
          Error Limit: 1.3% (Measured over center 6 divisions) 
          Input Impedance: (all models, all channels) 1 MΩ Â±1% // 25 pf ±2 pf 
          (PM 3390B/94B): user selectable 50Ω Â±1% 
          Max. Rated input voltage: In 1 MΩ position: 150 Vrms CAT II 
          In 50Ω position: 5 Vrms; 50V ac peak ( max of 50 mJ during any 100 ms interval. 
           
          Horizontal (Main & Delayed Timebases) Display Modes: Main Timebase (MTB), Delayed Timebase (DTB), Alternate Timebase ( MTB & DTB), X-Y Mode.
          Time Coefficients: (PM 3380B/3384B): 0.5 s/div to 50 ns/div in a 1-2-5 sequence or calibrated variable control, 1.25 s/div to 50 ns/div.
          (PM 3390B/3394B): 0.5 s/div to 20 ns/div in a 1-2-5 sequence or calibrated variable control, 1.25 s/div to 20 ns/div. 
          Fastest Sweep (Magn 10X): (PM 3380B/3384B) 5 ns/div
          (PM 3390B/3394B) 2 ns/div
          Error Limit (Magn 10X):  ±1.3% of reading + 0.5% of 8 divisions)
           
          Triggering (Main & Delayed Timebase) Trigger modes: Auto free run, Triggered, Single, Edge Triggering, TV Triggering 
           
          Edge Triggering MTB Trigger Source: (PM 3380B/3390B): Ch1, Ch2, Ext
          (PM 3384B/3394B): Any input channel or Line (mains); Optional rear mounted External Trigger input replacing line Triggering.
          DTB Trigger Source: Starts after delay or triggered on any input channel. 
          Slope: Positive or Negative 
          Coupling: DC, AC (> 10 Hz), LF-Rej (30 kHz), HF-Rej (30 kHz) 
          Level Range: ±8 div or level within signal peak to peak range. 
          Level Indication:  On screen level indicators and numeric readout.
          Trigger Sensitivity: (PM 3380B/3384B): 0.6 div up to 50 MHz, 1.2 div up to 100 MHz, 2.0 div up to 200 MHz
          (PM 3390B/3394B): 0.6 div up to 100 MHz, 1.2 div up to 200 MHz, 2.0 div up to 300 MHz 
           
          TV Triggering Video Standard: HDTV, NTSC, PAL, SECAM standards
          MTB Trigger Source: CH1 to CH4, Field1, Field2, TV-Lines 
          Signal Polarity: Positive or Negative 
          Sensitivity: 0.7 div (Sync Pulse) 
           
          Cursor Measurements Cursor Modes: Horizontal, Vertical, Both 
          Readout: Vertical: dV, V1 to gnd, V2 to gnd, Ratio 
          Horizontal: dt, 1/dt (in Hz), Ratio, Phase
          Accuracy (magn 1X): 1% of full scale within the central 8 horizontal and 6 vertical divisions.
           
          X-Y Mode X Deflection Source: Any input channel or line
          X Deflection Coefficient: Same as for vertical deflection 
          Dynamic range: 20 div up to 100 kHz, > 10 div up to 2 MHz. 
          Frequency Response: 32 MHz at -3 dB 
          Error Limit: 5% measured over central 6 divisions. 
          Phase Shift: < 3o up to 100 kHz 
           


           
          PM3380BDigital Mode Specifications
          Acquisition Repetitive Sample Rate: Random sampling gives an equivalent sample rate of up to; 
          (PM 3380B/3384B): 10 GS/s
          (PM 3390B/3394B): 25 GS/s
          Single Shot Sample Rate: Up to 200 MS/s
          Vertical resolution: ADC resolution: 8 bit
          Memory resolution: 16 bit
          Memory: (PM 3380B/3390B): Standard Memory: 8 k, max trace storage, 27 traces
          (PM 3380B/3390B): Extended Memory option: 32 k, max trace storage, 153 traces
          (PM 3384B/94B): Standard Memory: 32 k, max trace storage, 204 traces 
          Average:  2,4,8 to 4096, giving a resolution of up to 14 bits
          Peak Detection: Captures glitches up to 5 ns
          Envelope Mode:  For continuous tracking of changing waveforms 
           
          Vertical Auto Ranging vertical deflection: Automatically and continuously adapts the instrument's vertical settings to have 2 to 6 divisions' display of input signal.
          Bandwidth: See above analog mode specification 
          Magnification: Up to x32 magnification for higher deflection sensitivity. 
          Display modes: Ch1, ± Ch2, Ch3, ± Ch4, calculated add and subtract
          Window Mode: 2 or 4 windows to display two or four traces above each other while using the full dynamic range of the ADC 
           
          Horizontal Autoranging timebase: Continuously adapts timebase sweep speed to the frequency of the trigger signal in order to keep 2 to 6 cycles on screen. 
          Acquisition modes: Recurrent (Auto and triggered), Single Shot, Multiple Single Shot, Roll, Triggered Roll
          X-Y Mode: Any trace in memory or any of the input channels can be used as a X source. 
           
          Timebase Single Shot Sampling:  200 s/div to 500 ns/div in a 1-2-5 sequence
          Variable Timebase: Continuously variable sweep speed; 1us/div to 500 us/div in 1 us increments. 500 us/div to 200 s/div with 0.2% or smaller increments.
          Recurrent:  (PM 3380B/3384B): 200 ns/div to 5 ns/div 
          (PM 3390B/3394B): 200 ns/div to 2 ns/div
          Roll Mode: 200 s/div to 200 ms/div, triggered or free roll mode, in a 1-2-5 sequence or continuously variable 
          Display Resolution: Horizontal resolution for 1x magnification: 500 samples = 10 divisions = 1 screen width.
          Magnification: x2, x4 to x32 to zoom in onto parts of waveform
          Interpolation: Dots, Sine or Linear
           
          Triggering Trigger Coupling: Same as analog mode 
          Edge Triggering:  Same as analog mode plus; dual slope triggering available when in single shot, real time mode. 
          TV Triggering: Same as analog mode 
          Logic trigger modes: (PM 3380B/3390B): Glitch (time qualified pulse)
          (PM 3384B/3394B): State (4 bit), Pattern (4 bit), Glitch (time qualified pulse) 
           
          Delay Time Delay: 0 to 1,000 div continuously adjustable
          Pre trigger view: Up to a complete record can be filled with pre-trigger information. (160 div for 8 k, 640 division for 32 k) 
          Event Delay: 1 to 16,384 events, max count rate 50 MHz
          Delay Modes: Starts after time delay or wait for trigger after time delay.
           
          Cursor Measurements Cursor Modes: Horizontal, Vertical, Both: Free or locked to trace
          Readout: Vertical: dv, V1 to gnd, V2 to gnd, Ratio
          Horizontal: dt, 1/dt (in Hz), Ratio, Phase (cycle is automatically referenced to trigger signal) 
           
          Calculated Measurements Volt: DC, rms, minimum, maximum, peak to peak, Low level, High level, Overshoot (positive & negative), Pre-shoot (positive & negative)
          Time: Frequency, Period, Pulsewidth, Rise time, Fall time, Duty cycle 
          Delay: Channel to channel, rising and falling edges. 
          Quick Measurements Probe operated, "Touch Hold And Measure" instantly gives calculated measurements of frequency, dc, rms, and Vp-p.
           
          Processing Add, Subtract, Multiply, Digital Filter, Integrate, Differentiate, FFT, Histogram, Pass Fail.
           


          PM3380BGeneral Specifications
          Autoset Selects proper channel, time-base and trigger settings. Function can be customized
           
          Autocal Automatic fine adjustment for enhanced accuracy to get optimal performance even under extreme environmental conditions
           
          Interfacing Standard: RS-232C, CPL protocol 
          Options: IEEE-488.2(GPIB), SCPI
           
          Hard Copy Output: Printed or plotted hard copy of the screen in digital mode. 
          User Text: Two lines of on-screen text
          Interface: RS-232C or IEEE-488.2 (GPIB) 
          Printer Drivers: FX Series (9 Pin), LQ1500 (24 Pins), HP 2225 Thinkjet, HP Laserjet, (series II & III), HP 540 Deskjet, and compatibles.
          Plotters: HP 7440, HP 7550, HP 7475A, HP 7470A and compatibles, HPGL. 
          Camera: Camera Kit PM 9381/001 available as optional accessory. 
           
          Power Supply Line Voltage: 100V to 240V (±10%) CAT II 
          Line Frequency: 50 Hz to 400 Hz (±10%) 
          Power Consumption: 115W (130W with all options installed) 
           
          Safety Meets requirements of EN 61010-1 CAT II Pollution Degree 2, Low Voltage Directive 73/23/EEC, UL3111, CSA C22.2 010-1
          Meets requirements of MIL-STD-461C: Part2 CEO1 (narrow band), Part4 CEO3, Part2 CSO1, Part5 CSO6, (Limited to 300V), Part5 and 6 REO1, Part2 REO2 (max. 1 GHz)
           
          EMC 
          Miscellaneous Setting Memory: 10 complete instrument setups, with battery backup. 
          Calibrated output: 600 mv p-p, 2 kHz square wave. 
          Z-Modulation Input: BNC, 10 kΩ > 2.4V=blanked, < 0.5 V=unblanked 
          Time Between Calibration: 2000 Hrs or 1 year
          4000 Hrs or 2 year if error limits are doubled.
           
          Size (excluding handle & feet) 139 mm H x 341 mm W x 481 mm L
          5.5" H x 13.4" W x 18.9' L
           
          Weight  9.5 kg
          21 lb
           
          Warranty Three-year product warranty, parts and labor. Five year CRT warranty.
           

           

          在線咨詢

          留言框

          • 產(chǎn)品:

          • 您的單位:

          • 您的姓名:

          • 聯(lián)系電話:

          • 常用郵箱:

          • 省份:

          • 詳細地址:

          • 補充說明:

          • 驗證碼:

            請輸入計算結(jié)果(填寫阿拉伯數(shù)字),如:三加四=7

          掃碼添加微信

          • 蘇州高新區(qū)長江路436號綠寶商務樓2幢7003室
          • 聯(lián)系電話:0512-68051240
          • 公司郵箱:chunjing_liu@yoi-tech.com

          © 2025 詠繹電子科技(蘇州)有限公司(m.hfmutuo.com) 版權(quán)所有    

          技術(shù)支持:化工儀器網(wǎng)    管理登陸    sitemap.xml

          TEL:

          掃碼聯(lián)系我們