          INPUT
          Voltage 115/230 VAC ± 10%, User selection
          Frequency 50/60 Hz ± 5%
          Fuse 6.3 Amp 250V Slo-Blo
          DIELECTRIC WITHSTAND TEST MODE
          Output Rating 5 KV @ 20mA AC
          6 KV @ 5 mA DC
          Output Adjustment Range: 0-5 KV AC, 0-6 KV DC
          Resolution: 10 volt/step
          Accuracy: ± (2% of setting + 5 volts)
          Voltage Display Range: 0 - 5 KVAC / 0-6KV DC
          Resolution: 10 volt/step
          Accuracy: ± (2% of reading + 10 volts)
          HI / LO -Limit AC Range: 0.00 - 20.00 mA
          Resolution: 0.01 mA/step
          Accuracy: ± (2% of setting + 0.02 mA)
          AC Current Display Range: 0.00 - 20.00 mA
          Resolution: 0.01 mA/step
          Accuracy: ± (2% of reading + 0.02 mA)
          HI / LO -Limit DC Range: 0.00 - 5.00 mA
          Resolution: 0.01 mA/step
          Accuracy: ± (2% of setting + 0.02 mA)
          DC Current Display Range: 0.00 - 5.00 mA
          Resolution: 0.01 mA/step
          Accuracy: ± (2% of reading + 0.02 mA)
          Failure Detector Audible and Visual
          Output Ripple < 5% (6KVDC/5 mA at Resistive Load)
          Discharge Time ≦ 200 ms
          Maximum Capacitive Load in DC Mode 1µF < 1KV , 0.75µF < 2KV, 0.5µF < 3KV, 0.08µF < 4KV, 0.04µF < 5KV, 0.01µF < 6KV
          AC Wave Form Sine wave Distortion : < 2% THD ; Crest Factor= 1.3 – 1.5
          Output Frequency Range: 60 or 50 Hz, User Selection
          Output Regulation ± (1 % of output + 5 volts) from no load to full load
          Dwell Timer Range: 0, 0.2 - 999.9 sec, (0 = Constant)
          Resolution: 0.1 sec increments
          Accuracy: ± (0.1% + 0.05 sec)
          Ramp Timer Range: 0.1 - 999.9 sec
          Resolution: 0.1 sec increments
          Accuracy ± (0.1% + 0.05 sec)
          INSULATION RESISTANCE TEST MODE
          Output Voltage Range: 100 - 1000 Volts DC
          Resolution: 1 volt/step
          Accuracy: ± (2% of reading + 5 volts)
          Voltage Display Range: 0 - 1000 V
          Resolution: 1 volt/step
          Accuracy: ± (2% of reading + 2 counts)
          Resistance Display Range: 1 - 1000 MΩ (4 Digit, Auto Ranging)
          Resolution: 0.01/0.1 MΩ
          Accuracy: ± (3% of reading + 2 counts) at test voltage > 500V
          ± (7% of reading +2 counts) at test voltage < 500V
          HI-Limit Range: 0, 1 - 1000 M Ω (0 = Off)
          LO-Limit Range: 1 - 1000 M Ω
          Delay Timer Range: 0, 0.5 - 999.9 sec (0 = Constant)
          Resolution: 0.1 sec/step
          Accuracy: ± (0.1% + 0.05 sec)
          GROUND BOND TEST MODE
          Output Voltage Range: AC 6 volts Max.
          Output Frequency Range: 60 or 50 Hz, User Selection
          Accuracy: ±0.1%
          Output Current Range: 3.0 - 30.0 Amps AC
          Resolution: 0.1 Amp/step
          Accuracy : ± (2 % of setting + 0.1A)
          Current Display Range: 0.0 - 30.0 Amps
          Resolution: 0.1 Amp/step
          Accuracy: ± (3 % of reading + 0.1A)
          Resistance HI-Limit Range: 0 - 510 mΩ
          Resistance Display Range: 0 – 510 mΩ for 0.0 – 10.0 Amps
          0 – 200 mΩ for 10.1 – 25.0 Amps
          0 – 150 mΩ for 25.1 – 30.0 Amps
          Resolution: 1 mΩ/step
          Accuracy: ± (2 % of Setting + 2 mΩ )
          Dwell Timer Range: 0, 0.5 - 999.9 sec (0 = Constant)
          Resolution: 0.1 sec/step
          Accuracy: ± (0.1% + 0.05 sec)
          Lead Resistance Offset Max. Offset Capability: 100 mΩ
          Resolution: 1 mΩ / step
          Accuracy: ± (2 % of Setting + 2 mΩ )
          GENERAL SPECIFICATIONS
          PLC Remote Control Input - Test, Reset, Interlock & Recall Memory 1 - 6
          Output - Pass, Fail, Test-in-Process
          Memory Allows storage of up to 6 different test programs and 6 step/each memory and single step mode.
          Security Lockout capability to avoid unauthorized access to test set-up programs.
          Calibration Software and adjustments are made through front panel.
          Mechanical Bench or rack mount with tilt up front feet.
          Optional Arc Detection Hardware ACW and DCW; Software adjustable Arc Level 0-9
          Dimension 280(W) x 89(H) x 430(D) mm
          Weight 33 lbs. (15 kg)

          在線咨詢

          留言框

          • 產(chǎn)品:

          • 您的單位:

          • 您的姓名:

          • 聯(lián)系電話:

          • 常用郵箱:

          • 省份:

          • 詳細地址:

          • 補充說明:

          • 驗證碼:

            請輸入計算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7

          掃碼添加微信

          • 蘇州高新區(qū)長江路436號綠寶商務(wù)樓2幢7003室
          • 聯(lián)系電話:0512-68051240
          • 公司郵箱:chunjing_liu@yoi-tech.com

          © 2025 詠繹電子科技(蘇州)有限公司(m.hfmutuo.com) 版權(quán)所有    

          技術(shù)支持:化工儀器網(wǎng)    管理登陸    sitemap.xml

          TEL:

          掃碼聯(lián)系我們